Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 82(5): E718-25, 2013 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23592588

RESUMO

BACKGROUND: A novel percutaneous ventricular restoration therapy (PVRT) has been recently proposed to treat patients with ischemic heart failure (IHF) and antero-apical regional wall motion abnormalities after myocardial infarction (MI). In this prospective, single center, non-randomized study, we herein propose safety and feasibility evaluation of the device, in which a different patient selection strategy was used. MATERIAL AND METHODS: A three-stage evaluation was adopted in a series of patients referred for a Parachute Ventricular Partitioning Device (Parachute™). After an initial clinical evaluation, a secondary screening step was performed according to echocardiographic functional (LVEF<40%, apical/anterior akinesia/dyskinesia) and anatomical criteria [diameter of LV-apex (LVAD) = 4.0 × 5.0 cm, left ventricular end diastolic diameter (LVEDD)>56 mm, left ventricular end systolic diameter (LVESD)>38 mm]. Patients encountering the echocardiographic criteria were selected for 3D cardiac CT (architecture, geometry, and trabeculation of the left ventricle) and eventually treated with the Parachute™. RESULTS: Fifty patients were screened according to the echocardiographic criteria. Twenty-seven of those that met the echo inclusion criteria underwent further cardiac CT imaging. After CT imaging, eight patients were scheduled for Parachute™ implantation. The device was successfully implanted in all eight patients with no in-hospital mortality. A 3-month follow-up echocardiography showed LV-volume reduction [95% CI; LVEDV: -76.5 (-116; -36.8), P = 0.002 and LVESV: -47.4 (-63.8; -30.9), P = 0.003] and improvement of global EF [95% CI; global EF: 6.87 (5.36; 8.39), P = 0.008]. CONCLUSION: Selection criteria for Parachute™ placement should include left ventricular functional and anatomical parameters. When preprocedural echocardiography and cardiac CT are adequately implemented, satisfactory periprocedural and short term follow-up results may be achieved after Parachute™ implantation.


Assuntos
Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/terapia , Seleção de Pacientes , Idoso , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Estudos de Viabilidade , Feminino , Alemanha , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Infarto do Miocárdio/complicações , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...